1. 46BE 1/4" Free-field Set
    Freq range: 4 Hz to 80 kHz
    Dyn range: 35 dBA to 160 dB
    Sensitivity: 3.6 mV/Pa
    Use: For general acoustic diagnostics

    G.R.A.S. 46BE 1/4" CCP Free-field Standard Microphone Set

    The G.R.A.S. 46BE is a 1/4" Constant Current Power CCP free-field microphone set for measuring high sound pressure levels at high frequencies. It is terminated with a 10/32 UNC microdot female connector and is TEDS compatible. The equivalent traditional 200 V LEMO type is G.R.A.S. 46BF.

    Learn More
  2. 50AI-LP 1/2" CCP Rugged Intensity Probe
    Freq range: IEC 61043 Class 1
    Dyn range: 25 dB(A) to 152 dB
    Sensitivity: 12.5 mV/Pa

    G.R.A.S. 50AI-LP 1/2" CCP Rugged Intensity Probe

    The G.R.A.S. 50AI-LP 1/2" CCP Rugged Intensity Probe is an industrial sound intensity probe in a very robust design that makes it suitable for use in heavy industrial environment. The probe has remote control and direct connection to LMS data acquisition modules with ICP inputs.

    Learn More
  3. 50AI-L 1/2" CCP Intensity Probe
    Freq range: Ref. IEC 61043 Class 1
    Dyn range: 25 dB(A) to 152 dB
    Sensitivity: 12.5 mV/Pa

    G.R.A.S. 50AI-L 1/2" CCP Intensity Probe

    The G.R.A.S. 50AI-L 1/2" CCP Intensity Probe is a general purpose sound intensity probe with remote control and direct connection to LMS data acquisition modules with ICP inputs.

    Learn More
  4. 67TS Turbulence Screen Kit
    Turb. att.: Up to 25 dB*
    Turb. speed: Up to Mach 0.2
    Freq. range (turbulence) 500 Hz - 10 kHz*
    Acoustic att.: Less than 3 dB
    Directivity: ± 60 Deg
    *Depending on flow-speed

    G.R.A.S. 67TS Turbulence Screen Kit

    The G.R.A.S. 67TS Turbulence Screen Kit is designed for aeroacoustic testing in solid-walled wind tunnels. The hydrodynamic component of turbulence is attenuated up to 25 dB. Thereby the acoustic signals of interest can be identified and diagnosed with a reliable resolution.

    Learn More
  5. 67TS-1-CL Turbulence Screen Kit with Flush-mount Microphone
    Turb. att.: Up to 25 dB*
    Turb. speed: Up to Mach 0.2
    Turb. suppr. freq. range: 500 Hz - 10 kHz*
    Acoustic att.: Less than 3 dB
    Directivity: ± 60 Deg
    Freq. range (acoustic) 100 Hz - 70 kHz
    Dyn.range 44 dB(A) - 166 dB
    *Depending on flow-speed

    G.R.A.S. 67TS-1-CL Turbulence Screen Kit with Flush-mount Microphone

    The G.R.A.S. 67TS-1-CL Turbulence Screen Kit is designed for aeroacoustic testing in solid-walled wind tunnels. The hydrodynamic component of turbulence is attenuated up to 25 dB. Thereby the acoustic signals of interest can be identified and diagnosed with a reliable resolution.

    Learn More
  6. 50AI-D 1/2"  Intensity Probe
    Freq range: Ref. IEC 61043 Class 1
    Dyn range: 25 dB(A) to 152 dB
    Sensitivity: 25 mV/Pa

    G.R.A.S. 50AI-D 1/2" LEMO Intensity Probe

    The G.R.A.S. 50AI-D Sound-intensity Probe builds on more than 20 years of theory and practical experience in sound-intensity measurements. It is adjustable, durable and fully complies with the requirements in IEC 61043, Electroacoustics- Instruments for the Measurement of Sound Intensity- Measurements with Pairs of Pressure Sensing Microphones, 1993 for Class 1 Sound-intensity probes.

    Learn More
  7. 50AI-C 1/2"  Intensity Probe
    Freq range: Ref. IEC 61043 Class 1
    Dyn range: 25 dB(A) to 152 dB
    Sensitivity: 25 mV/Pa

    G.R.A.S. 50AI-C 1/2" LEMO Intensity Probe

    The G.R.A.S. 50AI-C Sound-intensity Probe builds on more than 20 years of theory and practical experience in sound-intensity measurements. It is adjustable, durable and fully complies with the requirements in IEC 61043, Electroacoustics- Instruments for the Measurement of Sound Intensity- Measurements with Pairs of Pressure Sensing Microphones, 1993 for Class 1 Sound-intensity probes.

    Learn More
  8. 50GI-RP CCP Rugged Intensity Probe
    Freq range: IEC 61043 Class 1
    Dyn range: 27 dB(A) to 163 dB
    Sensitivity: 12.5 mV/Pa

    G.R.A.S 50GI-RP CCP Rugged Intensity Probe

    Type 50GI-RP is a sound intensity probe for direct connection to signal analyzers or data acqusition devices with IEPE inputs. The probe includes a pair of phase-matched prepolarized precision microphones which meet the requirements in IEC standard 61043 for a class-1 intensity probe..

    Learn More
  9. 50GI-P CCP Rugged Intensity Probe
    Freq range: IEC 61043 Class 1
    Dyn range: 27 dB(A) to 163 dB
    Sensitivity: 12.5 mV/Pa

    G.R.A.S 50GI-P CCP Rugged Intensity Probe

    Type 50GI-P is a sound intensity probe for direct connection to signal analyzers or data acqusition devices with IEPE inputs. The probe includes a pair of phase-matched prepolarized precision microphones which meet the requirements in IEC standard 61043 for a class-1 intensity probe.

    Learn More
  10. 50GI-R Intensity Probe with Remote Control
    Freq range: IEC 61043 Class 1
    Dyn range: 27 dB(A) to 163 dB
    Sensitivity: 12.5 mV/pa

    G.R.A.S. 50GI-R CCP Intensity Probe with Remote Control

    The 50GI-R is a sound intensity probe for direct connection to signal analyzers or data acquisition devices with IEPE inputs. The probe includes a pair of phase-matched prepolarized precision microphones which meet the requirements in IEC standard 61043 for a class-1 intensity probe. The small rugged ¼" CCP preamplifiers ensure minimum disturbances to the sound field for accurate measurements in the full frequency range.

    Learn More
  11. 40PH Free-Field Array Mic
    Freq range: 10 to 20 kHz
    Dyn range: 32 dB(A) to135 dB
    Sensitivity: 50 mV/Pa

    G.R.A.S. 40PH CCP Free-field Array Microphone

    The G.R.A.S. 40PH Array Microphone is a low-cost microphone for general purpose measurements in arrays and matrices.

    Learn More
  12. 47AX 1/2'' CCP Flush-mount Mic Set
    Freq range: 3.15 Hz to 20 kHz
    Dyn range: 22 dB(A) to 150 dB
    Sensitivity: 12.5 mV/Pa

    G.R.A.S. 47AX 1/2'' CCP Flush-mount Microphone Set

    The G.R.A.S. 47AX 1/2" CCP Flush-Mount Microphone Set is a low profile 1/2" precision pressure microphone with built-in CCP preamplifier.

    Learn More
  13. 47BX 1/4" CCP Flush-mount Microphone Set
    Freq range: 4 Hz to 70 kHz
    Dyn range: 44 dB(A) to 166 dB
    Sensitivity: 1.6 mV/Pa

    G.R.A.S. 47BX 1/4" CCP Flush-mount Microphone Set

    The G.R.A.S. 47BX 1/4" CCP Flush-Mounted Microphone Set is a low profile 1/4" precision pressure microphone with built-in CCP preamplifier.

    Learn More
  14. 26CK 1/2'' CCP Standard Preamp, Very Short (Mdot)
    Freq range: 2.5 Hz - 200 kHz
    Noise: 1.8 µV
    Gain: -0.45 dB
    Special feature: For confined spaces

    G.R.A.S. 26CK 1/2” CCP Standard Preamplifier with Microdot Connector, Very Short

    The G.R.A.S. 26CK ½” Preamplifier, Very Short is a very small preamplifier optimized for use with prepolarized condenser microphones. It is a robust unit that uses a constant current power (CCP) supply. The 26CK has a very low inherent noise level, a large dynamic range, and a frequency response from below 2 Hz to above 200 kHz.

    Learn More
  15. 50GI CCP Intensity Probe
    Freq range: Ref. IEC 61043 Class 1
    Dyn range: 27 dB(A) to 163
    Sensitivity: 12.5 mV/Pa

    G.R.A.S. 50GI CCP Intensity Probe

    G.R.A.S. 50GI is a sound intensity probe for direct connection to signal analyzers or data acqusition devices with IEPE inputs. The probe includes a pair of phase-matched prepolarized precision microphones which meet the requirements in IEC standard 61043 for a class-1 intensity probe. The small rugged 1/4" CCP preamplifiers ensure minimum disturbances to the sound field for accurate measurements in the full frequency range.

    Learn More
  16. 50AI-B 1/2"  Intensity Probe
    Freq range: Ref. IEC 61043 Class 1
    Dyn range: 25 dB(A) to 152 dB
    Sensitivity: 25 mV/Pa

    G.R.A.S. 50AI-B 1/2" LEMO Intensity Probe

    The G.R.A.S. 50AI-B Sound-intensity Probe builds on more than 20 years of theory and practical experience in sound-intensity measurements. It is adjustable, durable and fully complies with the requirements in IEC 61043, Electroacoustics- Instruments for the Measurement of Sound Intensity- Measurements with Pairs of Pressure Sensing Microphones, 1993 for Class 1 Sound-intensity probes.

    Learn More
  17. 50VI-1 Vector intensity probe
    Freq range: IEC 61043 Class 1
    Dyn range: 25 dB(A) to 152 dB
    Sensitivity: 25 mV/Pa

    G.R.A.S. 50VI-1 Vector intensity probe

    The G.R.A.S. 50VI-1 Vector Intensity Probe is a flexible and adjustable, two or three-dimensional sound-intensity probe. The probe handle has marked inputs for 3 pairs of preamplifiers (a pair for each of the mutually-perpendicular directions) and a 24-pin LEMO output socket at its base for connecting it to a suitable Power Module (e.g. Type 12AC) or Power Modules (via cable adapter).

    Learn More
  18. 45BB-4 For Sound Quality Recording, 2-Ch CCP
    Connection: Constant Current Power (0 V/CCP)
    Channel(s): 2
    ANSI: S3.36
    ITU-T Rec. P.57 Type 3.3 based on ITU-T Rec. P.58

    G.R.A.S. 45BB-4 KEMAR Head & Torso for Sound Quality Recording, 2-Ch CCP

    The 45BB-4 KEMAR Head and Torso for Sound Quality Recording is an acoustic research tool with built-in 1/2" microphones for realistic sound quality testing and recordings. It is easy ro replace the 1/2" microphones with 1/4" microphones if preferred. Its LEMO equivalent is G.R.A.S. 45BB-3 KEMAR Head & Torso for Sound Quality Recording, 2-Ch LEMO.

    Learn More
  19. 45BB-3 For Sound Quality Recording, 2-Ch LEMO
    Connection: Traditional Power Supply (200 V/LEMO)
    Channel(s): 2
    ANSI: S3.36
    ITU-T Rec. P.57 Type 3.3 based on ITU-T Rec. P.58

    G.R.A.S. 45BB-3 KEMAR Head & Torso for Sound Quality Recording, 2-Ch LEMO

    The 45BB-3 KEMAR Head and Torso for Sound Quality Recording is an acoustic research tool with built-in 1/2" microphones for realistic sound quality testing and recordings. It is easy ro replace the 1/2" microphones with 1/4" microphones if preferred. Its CCP equivalent is G.R.A.S. 45BB-4 KEMAR Head & Torso for Sound Quality Recording, 2-Ch CCP.

    Learn More
  20. RA0020 1/2" Nosecone

    Length: 54.0 mm
    Outer diameter: 13.2 mm
    Threading (mic. protection grid threading): 12.70-60 UNS-2
    Material: Stainless steel
    Weight: 45 g

    G.R.A.S. RA0020 1/2" Nosecone

    The RA0020 is specially designed and optimized for use with 1/2" microphones for sound pressure measurements, when high speed wind comes from one known direction e.g. in a wind tunnel.
    Learn More

Items 1 to 20 of 24 total